Use a rigid, verified foundation
Centrifuges generate dynamic loads. The foundation, anchor bolts and grout must follow the equipment interface requirements and local structural design.
Keep connected piping flexible
Rigid piping can transmit loads and vibration into the machine. Connections for feed, wash liquid and drainage should accommodate movement while remaining chemically compatible.
Test every safety function
Lid locks, overspeed protection, braking, emergency stop and vibration monitoring must be verified before product is introduced. Guards should remain fitted during operation.
Train for balanced loading
Operators need a standard loading, washing and discharge routine. Uneven loading, blocked drainage and neglected cleaning can reduce separation quality and increase vibration.